Our OMNIA Series is a complete line of multi-function Electrical Safety Testers designed to satisfy even the most demanding application requirements. We’ve included exclusive productivity-enhancing features and the latest in safety technology to make this product line the envy of the industry. From medical devices to appliances, OMNIA II’s all-in-one design includes the test functionality you need to ensure your product is compliant with the most rigorous international safety compliance standards. The OMNIA II is the Dielectric Withstand Tester ready for global deployment. It has a wide array of test capabilities, a multi-language menu system and a variety of automation interfaces available. The OMNIA II Series includes the following models: 8204, 8254, 8206, 8256, 8207, 8257.
Fully integrated AC/DC withstand (ACW/DCW), insulation resistance (IR), AC ground bond (AC GB), ground continuity (GC), touch current (TC), and run testing (RT) features combine in a single solution. The series blends multiple combinational testing tools with one-step testing functionality to increase test efficiency.
DualCHEK functionality supports simultaneous execution of hipot and ground bond testing to improve testing efficiency.
AR exclusive patent right on fast discharge function to help DUT expeditiously releases any excess electricity within 50ms, ensuring maximum operator safety.
The tester is capable of performing hipot tests while the DUT is powered on, and complies with China Standard GB/T 12350-2009 for more demanding quality tests.
Seven different human-body-simulation measuring devices (MD) create a diversity of possibilities for replicating real-world conditions.
Specifications
AC Hipot Voltage Output = 0-5000VAC Leakage Current Limits = 0.001-50.0mA Output Frequency = 50/60Hz
AC Hipot Voltage Output = 0-5000VAC Leakage Current Limits = 0.001-100.0mA Output Frequency = 50/60Hz
DC Hipot Voltage Output = 0-6000VDC Leakage Current Limits = 0.0µA-20.00mA DC Ripple = ≤ 4% Ripple RMS at 5KVDC @ 20mA, Resistive Load
Ground Bond Output Voltage = 3.0-8.0VAC Output Current = 1.00-40.0AAC Resistance Range = 0-600mΩ
Ground Continuity DC Output Current = 0.001A -0.1ADC Resistance Range = 0.000-10,000Ω
Insulation Resistance Voltage Output = 30-1000VDC Resistance Range = 0.05MΩ-50.0GΩ
Leakage Current Test Voltage Meter = 0-277VAC Current Meter = 0-16AAC Leakage Current (RMS) = 0.1µA-10.00mA Leakage Current (Peak) = 0.1µA-10.00mA Fault Conditions = Neutral Switch, Ground Switch, Polarity Reversal Switch
Measuring Devices (MDs) = UL544NP, UL484 , UL923, UL471, UL867, UL697, UL544P, IEC 60601-1, UL1563, IEC60990 Fig4 U2, IEC 60950-1, IEC60335-1, IEC60598-1, IEC60065, IEC61010, IEC60990 Fig5 U3, IEC60598-1, IEC60950, IEC61010-1 FigA.2 (2K ohm) for Run function.
500 VA AC Power Source Power = 630VA and 500W Max. Voltage Output = 0-277.0VAC Current Output = 0.00-4.20AAC Frequency Output = 45.0-500Hz.